BLUEDRIVE Coolant Circulation Systems

NIMBUS™ BLUEDRIVE® Coolant Circulation Systems work with all open and closed cooling systems. BLUEDRIVE systems are compatible with both open-loop and closed-loop cooling architectures, allowing facilities to integrate circulation upgrades into existing infrastructure while supporting future expansion or cooling system modernization strategies. BLUEDRIVE systems are available independently and accommodate a wide variety of gallon-per-minute needs as well as specific job, location and building requirements.

How It Works

The BLUEDRIVE coolant circulation system delivers optimal performance for both open and closed-loop systems, offering the reliability, safety and easy maintenance customers demand.

Featuring close-coupled pumps, it ensures consistent, dependable flow. The system’s integrated city water make-up manifold, check valves, isolation valves and expansion tank form a complete, ready-to-install solution that reduces on-site installation costs.

Built-in wye strainers, pressure relief valves, and automatic air vents keep the system clean, safe and running efficiently. With onboard pressure and temperature gauges, customers can easily monitor and troubleshoot their system in real time, ensuring smooth operation with minimal downtime.

Why It's better

BLUEDRIVE Coolant Circulation Systems are custom-engineered to provide streamlined flow and unmatched reliability. By selecting a single-source fluid cooler and pump module package, facilities benefit from seamless compatibility, minimizing maintenance and simplifying troubleshooting. The system’s intuitive design ensures faster, hassle-free installation, significantly reducing on-site installation costs and maximizing operational efficiency.

BLUEDRIVE systems are engineered, designed and manufactured by NIMBUS Advanced Process Cooling in the USA.

Built for Real-World Conditions

BLUEDRIVE coolant circulation systems are engineered to support complex cooling infrastructure where reliability, flexibility, and long-term maintainability are critical.
  • Constrained urban and retrofit sites: Modular skid layouts simplify installation in tight mechanical rooms, rooftops, equipment yards, and existing facilities where available footprint is limited.
    Industrial and debris-prone environments: Integrated inline strainers help protect pumps and downstream cooling equipment from particulate and debris commonly found in industrial operations, manufacturing environments, and outdoor installations.
  • Redundancy and uptime strategies: Optional dual-pump configurations, alternating pump operation, and automatic switchover controls support continuous coolant circulation during maintenance events or unexpected interruptions.
  • Phased facility expansion: Configurable piping layouts and modular circulation design allow facilities to expand cooling infrastructure over time without requiring complete system replacement.
  • Integration with multiple cooling technologies: BLUEDRIVE systems are designed to integrate with dry coolers, hybrid adiabatic systems, and existing open-loop or closed-loop cooling infrastructure, allowing facilities to adapt cooling strategies as operational needs evolve.

Features & Benefits

  • Pre-Assembled Units minimize field assembly time and on-site labor expenses
  • An Inline Strainer for each pump protects equipment from debris
  • Automatic Water Makeup Manifold maintains consistent water level
  • Air Scoop keeps air out and increases quality of water flow
  • Bladder-Type Expansion Tank allows for expansion and contraction as water temperatures fluctuate
  • Wide Range of Pipe Sizes and Materials (copper, stainless steel or SCH40 steel) meet the needs of any application
  • Single or Dual Centrifugal Pumps are sized to accommodate most specifications
  • Grooved Coupling System keeps maintenance and system reconfiguration hassle-free
  • Optional Alternating Pump Operation and Automatic Switchover Controls support redundancy planning, maintain continuous coolant circulation, and simplify maintenance scheduling
  • Optional Emergency City Water Fill and Drain Manifolds integrate with city water systems in case of power loss
  • Modular Circulation Configurations support phased facility expansion, redundant pumping strategies, and evolving cooling infrastructure requirements without requiring complete system redesign
Bluedrive system 2
Bluedrive system

Applications

Industrial

  • HVACR
  • Data Centers
  • Food Processing
  • Wineries & Distilleries
  • Grow Facilities
  • Automotive Manufacturing
  • Chemical Processing
  • Thermoplastic
  • And Others

Commercial & Institutional

  • Schools & Universities
  • Hospitals/Health Care
  • Government & Military
  • Airports/Transportation Hubs
  • High Rise Towers
  • Shopping Centers/Retail
  • Restaurants
  • Correctional Facilities
  • Casinos

Configurations

Contact us today to learn how BLUEDRIVE coolant circulation systems can be tailored for your operational requirements.

BLUEDRIVE systems can be configured around site-specific mechanical, spatial, and operational requirements, helping facilities simplify coolant circulation layouts in both new construction and retrofit applications.

All NIMBUS cooling systems are backed by our industry-leading 2-year warranty*

Driven to Be Blue

Be Blue is our conservation rallying cry.

Be Blue represents the NIMBUS philosophy of providing alternative, practical and economical cooling solutions that preserve water, energy and health.

Let’s develop the best cooling solution for your next project together.